Product Details:

  • Panel Type Modular
  • Control System Electronic sensing circuit
  • Protection Level High Sensitivity to Earth Leakage
  • Protection Class Class II
  • Thickness 45 mm
  • Rated Insulation Voltage 500V
  • Rated Operation Voltage 230V-400V AC
  • Click to View more
X

Electronic Low Voltage Residual Current Devices Price And Quantity

  • 1 Piece

Electronic Low Voltage Residual Current Devices Product Specifications

  • 230V-400V AC
  • 16A, 25A, 40A, 63A, 80A, 100A
  • IEC/EN 61008-1
  • Polycarbonate
  • Residual Current Device (RCD)
  • High Sensitivity to Earth Leakage
  • Electronic sensing circuit
  • Modular
  • Polycarbonate, Flame retardant plastic
  • IP20
  • Low voltage protection, Residential, Commercial, Industrial
  • 500V
  • 45 mm
  • Class II
  • 100A
  • High breaking capacity, Earth leakage protection, Compact design, Flame retardant, Test function, Mechanical indicator
  • White/Grey
  • 50-60 Hz
  • Double Pole (DP), Four Pole (FP)
  • No Display
  • 230/400V AC
  • 230/400V AC
  • Non-metallic enclosure
  • 85 x 74 x 44 mm
  • Thermoplastic
  • 16A to 100A
  • Screw Terminal
  • Bimetallic trip, Test button, Automatic reset
  • Natural Air Cooling
  • Matte

Electronic Low Voltage Residual Current Devices Trade Information

  • 100 Piece Per Month
  • 4 Week

Product Description



Redeem unparalleled electrical safety with our must-have Electronic Low Voltage Residual Current Devices. Astounding in both function and design, these potent devices feature meritorious sensitivity options of 30mA, 100mA, and 300mA, safeguarding residences and industries alike. With a high short circuit capacity of 6kA and a tripping time of 0.1 seconds, protection is never ephemeral. Built from flame-retardant, high-grade polycarbonate, and engineered for more than 10,000 mechanical operations, this compact, DIN rail-mounted marvel promises reliability. CE-marked and compliant with IEC/EN 61008-1, it is the ultimate solution for robust, enduring low voltage protection.

Comprehensive Protection for Multiple Sectors

Electronic Low Voltage Residual Current Devices offer a clear advantage in electrical protection for residential, commercial, and industrial environments. Their meritorious design ensures potent sensitivity to earth leakage, making them suitable for various applications where safety is paramount. Effortless DIN rail mounting and a compact footprint accommodate both new installations and upgrades. These devices are ideal for fabricators, service providers, and manufacturers seeking dependable, high-performance circuit protection with minimal maintenance requirements.


Widespread Market Availability & Seamless Order Process

Our Electronic Low Voltage Residual Current Devices are delivered promptly to both domestic clients throughout India and major export markets globally. Dealers, suppliers, service providers, and wholesalers can easily initiate purchase orders, ensuring timely order completion and consistent supply. The process is streamlined for bulk procurement, catering to diverse market needs. Flexible payment terms allow businesses to manage cash flows effectively while securing these essential protective devices for their projects.


FAQs of Electronic Low Voltage Residual Current Devices:


Q: How does an Electronic Low Voltage Residual Current Device work?

A: The device monitors electrical currents and trips the circuit automatically when it detects earth leakage exceeding the set sensitivity, thereby preventing electrical shocks and fires.

Q: What are the primary benefits of using this device in residential or industrial setups?

A: It provides high sensitivity earth leakage protection, compact installation, durable operation, and reduces risks of electrical hazards in various environments.

Q: Where can these devices be installed?

A: They are suitable for residential buildings, commercial complexes, and industrial facilities, integrating seamlessly with modular panels using DIN rail mounting.

Q: When should the test button on the device be used?

A: The test button should be used periodically, typically every three months, to verify the proper function of the device and ensure reliable protection.

Q: What is the typical process for purchasing and delivery?

A: Clients can submit a purchase order through authorized dealers or suppliers. Upon order completion, the devices are delivered, supported by flexible payment options.

Q: How durable is the device during frequent operations?

A: The device offers more than 10,000 mechanical operations and over 4,000 electrical operations, ensuring longevity even in demanding environments.